Basic Info.
  • Theory: Current Sensor 
  • Output: Analog Sensor 
  • Usage: Magnetic Sensor 
  • Brand Name: Acrel 
  • Product name: current transducer 
  • Brand: OEM ODM 
  • Power supply: AC85-265V,DC100-350V/DC 24V /DC 48V 
  • Warranty: 2Years 
  • Response time: <400ms 
  • Dimension(L*W*H): 138*76*24mm 
  • Installation: Din rail mounted 
  • Optional function: RS485 modbus-rtu communicaiton 
  • Place of Origin: Jiangsu  
  • Min.Order: 1 Piece/Pieces
  • Means of Transport: Ocean, Air
Supply Capacity
  • Production Capacity: 1000 pieces per week
  • Packing:Products are packed in carton box with air bubble film
  • Delivery Date: 3-5 working days after payments received

whatsapp 0086-18860990013

Product Description
BD-AI Single Phase Current Transducer

General

BD series current transducer isolate and convert electrical parameters (e.g.current,voltage,frequency,power and power factor) in the power grid into DC analog signal or digital signal.The product complies with GB/T13850-1998 and IEC-688.

Features
- Measure AC current
- Overload: 1.2 times of rated value
- Analog Output DC 0-5V/0-10V/0-20mA/4-20mA

-RS485 (Modbus-RTU) communication

-Power monitoring application

Technical Parameters

 

Technical parameters

Value

Accuracy

0.5class,0.2class

Input

Nominal value

Current :AC,DC 1A,5A;

Voltage: AC,DC 100V,300V,500Vand so on

Overload

Continual 1.2 times, Instantaneous current 10 times/5s;Instantaneous voltage 2 times /30s

Absorbed power

≤0.3VA(Current input);Voltage input≤0.3VA(100V),≤0.6VA(300V),≤1VA(500V)

Frequency

50±5Hz,60±5Hz

Output

Nominal value

DC:4-20mA,0-20mA, 0-5V, 0-10Vand so on

Load Resistance

Current output ≤600Ω

Voltage output ≥1000Ω

Ripple content

<0.5% peak value

Response time

≤400ms

Power supply

Voltage

AC85-265V/DC100-350V/DC24V/DC48V

Power

AC current, Voltage class ≤3VA,

Power Class ≤4VA

Insulation Resistance

≥100MΩ

Isolation voltage

(Among input//output//power supply)2.0kV/1min,50Hz

Temperature coefficient

 

0.5class≤200ppm/℃; 0.2class≤100ppm/℃

E  Environment

 

Temperature

Working:-10℃~+55℃ Storage:-25℃~+70℃

Humidity

≤90%RH,(In the place without dew and corrosive gas)

Altitude

≤2000m

Installation

 

(TS35 rail mounting, or attached with screws in of the cabinet)

 

Product Specification

Name

Model

Function

Optional Function

Current Transmitter

BD-AI

Measurement of single-phase AC current, isolation transmission output 4-20mA or 0-5V DC signal

RS485-MODBUS(C)

BD-3I3

Measurement of three-phase alternating currents transmission output isolation 4-20mA or 0-5V DC signal

/

Voltage transmitter

BD-AV

Measuring AC voltage isolation transmission output 4-20mA or 0-5V DC signal

RS485-MODBUS(C)

BD-3V3

Three-phase three-wire voltage transmitter, measuring three-phase AC voltage isolation transmission output 4-20mA or 0-5V DC signal

/

BD-4V3

Phase four-wire voltage transmitter, measuring three-phase AC voltage isolation transmission output 4-20mA or 0-5V DC signal

Power transmitter

BD-4EA

Three-Phase four-wire multi-power transmitter, measuring and displaying exports three-phase current, voltage ,active power, reactive power ,frequency ,power factor, active energy; reactive energy and so on, 1~4 channel analog  optional, two channel electric energy

pulse output,RS485-MODBUS

M- Analog output, selectable 1 channel, 2- channel, 3- channel, 4- channel

Frequency transmitter

BD-F

Measure frequency, transmit frequency into linear DC signal output

/

Active power transmitter

BD-3P

Three-Phase 3-wire,Measurement of active power, isolation analog signal transmission output

/

BD-4P

Three-Phase 4-wire,Measurement of active power, isolation analog signal transmission output

/

Reactive power transducer

BD-3Q

Three-Phase 3-wire,Measurement of reactive power, isolation analog signal transmission output

/

BD-4Q

Three-Phase 4-wire,Measurement of reactive power, isolation analog signal transmission output

/

P / Q combination transmitter

BD-3P/Q/I

Three-Phase 3-wire,Measuring current, active power, reactive power, isolate analog signal transmission output

/

 



Send message to this supplier
Mr. Sandra
Tel: 86-510-86179939
Mobile: 18860990013
Enter between 20 to 3,000 chatacters.
Contact Method
Jiangsu Acrel Electrical MFG Co., LTD
No.5 Dongmeng Road, Nanzha Street,Jiangyin City, Wuxi, Jiangsu, China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center