New Color OLED Fingertip pulse oximeter CE FDA

Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews
Basic Info.
  • Model No.: CMS50E 
  • Place of Origin: Hebei  
  • Min.Order: 1 piece
Supply Capacity
  • Production Capacity: 15000
  • Packing:carton
  • Delivery Date: ii five days
Fingertip Pulse Oximeter Blood Oxygen Pulse Rate SPO2 LED


Major Features
1.Integrated with SpO2 probe and processing display module
2.Operation of the product is simple ,low power consumption
3.Operation menu for the function setting
4.SpO2 value display
5.Pulse rate value display, bar graph display
6.Pulse waveform display
7.The display mode can be changed
8.Screen brightness can be changed
9.A pulse rate sound indication
10.With measured data overruns limits and low-voltage alarm function,the upper/down alarm range can be adjustable
11.Low-voltage indication: low-voltage indicator appears before working abnormally
which is due to low-voltage,and with alarm function
12.With SpO2 value and pulse rate value of storage, the storage data can be uploaded to
computers)Real-time data can be transmitted to computers
13.Automatically power off function: when the device is under the state of measuring interface .
it will automatically power off within 5 seconds if the finger falls out of probe.
14.RF Wireless communication function(option)(only applied for Ver6.6R or above )
15.Connected with an external oximeter probe(option)(CMS50EW,only applied for Ver6.6R or above of CMS50E

Main performance

Display Mode:1.3" 65K Color OLED display
Screen Resolution:128*96
SpO2 Measuring Range:0%~100%, (the resolution is 1%).
Accuracy:70%~100%:±2% ,Below 70% unspecified.
PR Measuring Range:30bpm~250bpm, (the resolution is 1bpm)
Accuracy:±2bpm or ±2% (select larger)
Measurement Performance in Weak Filling Condition:SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
Resistance to surrounding light:The deviation between the value measured in the condition
of man-made light or indoor natural light and that of darkroom is less than ±1%.
Power Consumption:less than 100mA
Voltage:DC 3.6V~4.2V
Power Supply:Voltage 3.7 rechargeable lithium battery × 1
Battery working hour:20 hours
Battery working life:Charge and discharge no less than 500 times.Safety Type:Interior Battery,BF Type
Accessories
Sell in standard
a hanging rope
a user manual
a data line
a disk (PC software)
a power adapter (GTM41076-0605;CMS0105)
Sell in addition
Oximeter Probe(Refer to probe application instruction for details and notice renewal)
RF Wireless Module"(only applied for Ver6.6R or above of CMS50E)
Physical Identity
Dimension:57(L) × 32(W) × 30 (H) mm
Weight:About 50g (with the lithium battery*1)

Qualification:CE&FDA&ISO


Send message to this supplier
Mr. Blair (sales manager)
Tel: 86-335-7788304
Enter between 20 to 3,000 chatacters.
Contact Method
Contec Medical Syatems CO,.LTD
#24Huanghe West Road ,E&T Development Zone ,Qinhuabgdao, Qinhuangdao, Hebei, China (Mainland) / 066000
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center