The airway pressure is showed directly and reduced automatically.
Air-Oxygen Mixer
Low-pressure Alarm
High pressure Pause
Standard configuration: Ventilator (including air-oxygen mixer, automatic airway pressure relief valve), oxygen cylinder, portable bag, face mask, endotracheal tube, laryngoscope, phlegm suction pot, humidifier, nasal oxygen cannula, the union pipe of phlegm-suction (wet), airway opener, oxygen refill fitting, wrench.
Physical parameter
Weight of Main Device: 0.70kg
Volume of Main Device: 178*46*68mm
Weight of Gas Cylinder: 2.5kg
Volume of Gas Cylinder: 2L
Main technical indicator
Breathing Mode: IPPV; A/C; Manual
Operating Pressure: 0.35--0.40 MPa
Minute Volume of Ventilation: 2--24 L/min
Respiratory Rate: 10--60 times/min (Adjustable in succession)
Five Indication: 10, 15, 20, 30, 40, 50, 60 times/min
Tidal Volume: 200--1000ml / time (Adjustable in succession)
Five Indication: 200, 400, 600, 800, 1000ml
I /E Ratio: 1: 2
Oxygen Concentration: Below 60%
Inspiratory Trigger: Below -1.5 Kpa
Low Pressure Alarm: Below 0.25 MPa
High Pressure Pause: 0.9--1.1 MPa
Reverse Flow Pressure of Airway: Below 6 KPa
Noise of Main Device: 65dB
Supply Flow of Gas Cylinder: 60 L/min
Continuous Working Time of Cylinder: Around 60min
Oxygen Storage Pressure for Cylinder: 14.7 MPa
Oxygen Consumption: Adult no more than 2 Cylinders/24h
Cylinder Specification: 12250 Kpa/40L
Protective Function
Airway Pressure Display: Visual
Low Pressure Alarm: Warning when supply pressure drops below 2.6bar
Airway Pressure Release Valve: Reducing pressure automatically when airway pressure exceeds 50cmH2O
High Pressure Protection: When high pressure inlet or airway pressure clogging, the ventilator will stop working following audible alarm voice.
(Respiratory Rate, Tidal Volume, I: E Ratio, Oxygen Concentration, Inspiratory Trigger are subject to a tolerance of 15%)

Send message to this supplier
Ms. elly
Tel: 86-371-63288588
Enter between 20 to 3,000 chatacters.
Contact Method
Henan Huirui Biomedical Electronics Co.,LTD
9th Floor,Yingte Building,Nongye Road, Zhengzhou, Henan, China (Mainland)
Fax: 86-371-65732188
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center