Generating set model | CDD[S/L]-30 | ||
Prime | Standby | ||
Gen-set power (KW) | 30 | 33 | |
Gen-set power (KVA) | 38 | 41 | |
Engine power (KW) | 46 | ||
Engine model | TD226B-3D | ||
Engine manufacturer | Sino-Germany joint venture weichai-deutz co.,ltd | ||
Engine configuration | 3-cylinder in line, 4-stroke, spontaneously inspiration, direct spray fuel system | ||
Engine cooling mode | The Radiator suitable for 40°CTemperature, Strap drive the cooling fan with protection cover | ||
Speed control system | Mechanical speed controller, electricity - magnet valve control switch | ||
Start mode | 24V Direct Current Start, Including alternator & battery | ||
Engine filter system | Dry air filter type, Fuel filters, Lube filter | ||
Engine total displacement (L) | 3.12 | ||
Compress ratio | 16.0/1 | ||
Bore*stroke (mm) | 105×120 | ||
100%load fuel consumption (L/h) | 9.6 | 10.6 | |
Specific fuel consumption (g/kwh) | ≤208 | ||
Lubricating oil consumption (g/kwh) | ≤1.36 | ||
Exhaust air flow (m3/min) | 60 | ||
Air consumption (m3 /min) | 2.8 | ||
Exhaust gas flow (m3/min) | 6.3 | ||
Exhaust gas temperature (°C) | 455 | ||
Oil capacity (L) | 7.25 | ||
Coolant capacity (L) | 15.5 | ||
Short circuit protection | MCCB Air switch | ||
Rated voltage/frequency/power factors | 400V/230V,50Hz,0.8 lag, 3-phase & 4-line | ||
Stable frequency change rate | ≤5% | ||
Free load voltage adjusting range | ≥95%—105% | ||
Stable voltage regulator | ≤±1% | ||
Insulation class/protection grade | Hclass/IP23 | ||
Telephone influence factor | TIF<50/ THF<2% | ||
Accessory attached | A suit of start battery& connective wire; Exhaust smoke siphon, Ripple absorber, Flange, Muffler; absorber on base | ||
Water tank ventilation area (mm) | 520*540 |
operation
After diesel generator installed, you can put into power, before each start, at least the following items should be checked
1.whether unit surface and around has debris
2.keep the into and exhaust channel of the engine room is smooth
3.the cooling liquid tank is normal
4.the air filter indicator directs normal
5.lubricating oil level is within normal range
6.the fuel valve is open, the supply of fuel to engine is normal
7.battery cables are connected correctly
8.power load device is ready,when the generator directly with the load, breaking the air switch before start.
2.keep the into and exhaust channel of the engine room is smooth
3.the cooling liquid tank is normal
4.the air filter indicator directs normal
5.lubricating oil level is within normal range
6.the fuel valve is open, the supply of fuel to engine is normal
7.battery cables are connected correctly
8.power load device is ready,when the generator directly with the load, breaking the air switch before start.