XLPE Insulated (Armoured) Power Cable

Trade Term: FOB
Payment Terms: T/T,L/C
Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews
Basic Info.
  • Application: Others 
  • Type: Insulated 
  • Insulation Material: PVC 
  • Conductor Material: Copper 
  • Conductor Type: Stranded 
  • Brand Name: Win-Win 
  • Place of Origin: Guangdong  
  • Min.Order: 2 Kilometer
  • Means of Transport: Ocean
Supply Capacity
  • Production Capacity: 100km per month
  • Packing:Sea Worthy Wooden Drum
  • Delivery Date: As quantity
Standards
The cable meets the standard requirements of GB/T12706-2002 or IEC60502-1997.
It is suitable to be installed in the power line with rated voltage of 0.6/1kV U0/U (Um).
Using properties
1.The maximum rated temperature
The maximum operating temperature of cores shall not exceed 90℃ when the cable is
used for long period.
The temperature of cores shall not exceed 250℃ at short circuit for 5 seconds.
2. Installation requirement
The installation of cables is not limited by the difference of level along the route.
The ambient temperature should not be below 0℃ during installation.
The permissible bending radius for cable shall not be less than 10 times of the cable
diameter. The single cable shall be without amour or with steel wire amour when it is
electrified with alternating current and shall not be laid in magnetic ducts.
3.6~35kV XLPE Insulated Power Cable
Standards
The cable meets the standard requirements of GB/T12706-2002 or IEC60502-1997.It is suitable
to be installed in the power line with rated voltage from U0/U(Um) of 3.6/6(7.2)KVto 26/35(40.5)KV.
Using properties
Earth fault permissible duration
The operating systems are divided into three categories available for selecting cable
Category A: When any phase is earthed, the cable can be departed from the system within 1 minute.
Category B:The earth fault duration each time does not exceed one hour, the accumulated time shall not exceed 125 hours each year.
Category C: Excluded categories from A and B.
The maximum rated temperature
The maximum operating temperature of cores shall not exceed 90℃ when the cable is used for long period. The temperature of cores shall not exceed 250℃ at short circuit for 5 seconds.
Installation requirement
The installation of cables is not limited by the difference of level along the route. The ambient temperature should not be below 0℃ during installation. The permissible bending radius for cable shall not be less than 10 times of the cable diameter. The single cable shall be without amour or with steel wire amour when it is electrified with alternating current and shall not be laid in magnetic ducts.
Technical parameters                                                                                                           3.6/6(7.2)kV XLPE insulated power cable                                                                 6/6(7.2)kV & 6/10(12)kV XLPE insulated power cable
8.7/10(12)kV & 8.7/15(17.5)kV XLPE insulated power cable
12/20(24)kV XLPE insulated power cable
8.7/10(12)kV XLPE insulated power cable
18/30(36)kV XLPE insulated power cable
21/35(40.5)kV XLPE insulated power cable                                                                         26/35(40.5)kV XLPE insulated power cable