1 used in high pressure pneumatic control system and general pipeline;
2: according to the selection principle of pneumatic control system to select the highest working pressure reducing valve, pressure ratio pressure reducing valve maximum output pressure 0.1Mpa;
The 3 valve features: convenient adjustment, stable performance, safe and reliable.
4 installation requirements: 1) valve installed as much as possible to install vertical direction; 2) reducing valve combination use, should pay attention to the order, namely, air filter, decompression valve, the oil mist device; 3) when used alone should pay attention to clean the air, or to the use of air filter installed 4); to release the handle, so that the pressure regulating spring is in a free state.
5 adjust and use in the ventilation in the lock nut before release handle, and then adjust the handle counterclockwise rotation, until the spring is in a free state so far, then open the valve on the inlet, began ventilation, and will adjust the handle clockwise rotation, adjusting pressure straight back to the pressure gauge readings arrive for now, after adjustment, tighten the lock nut, the adjustment of the flow is static, work will change in the flow state.
TechnicalData | |||||
Tybe | QTYH-08 | QTYH-10 | QTYH-15 | QTYH-20 | QTYH-25 |
Operatingfluid | Air | ||||
Joint pipebore | G1/4 | G3/8 | G1/2 | G3/4 | G1 |
Range ofadjustuble Pressure | 0.05~3.5MPa | ||||
Max.inputpressure | 4MPa | ||||
Operatingtemperature range | –25 ~ +80℃ |