1.Standard
The control cable can be produced according to the standardGB9330-1988,IEC,DIN,BS,and the factory can also manufacture the cables inaccordance with other standards.
2.Scope of Application
The control cable are suitable for the wiring of electricalcontrolling equipments and instrument,monitoring and controlling returncircuit,electrical protection and measurement in power distribution unit underthe circumstance that the rated voltage is up to 450/750V AC.
3.Type& Specification
Type | Name | Section Area(mm2) | No. of Core | Application Site |
KVV | Copper Conductor,PVC Insulated and Sheathed Control Cable | 0.75 1.0 1.5 2.5 | 2-16 | Permanent installation indoors,in cable ditches orpipes |
4 6 | 2-14 | |||
10 | 2-10 | |||
KVVP | Copper Conductor,PVC Insulated and Sheathed,Braiding Shielded Control Cable | 0.75 1.0 1.5 2.5 | 2-61 | Permanent installation indoors,in cable ditches or pipes whereshielding is required |
4 6 | 2-14 | |||
10 | 2-10 | |||
KVVP2 | Copper Conductor,PVC Insulated and Sheathed,Copper-tape ScreenedControl Cable | 0.75 1.0 1.5 2.5 | 4-10 | Permanent installation indoors,in cable ditches or pipes whereshielding is required |
4 6 | 7-61 | |||
10 | 4-10 | |||
KVV22 | Copper Conductor,PVC Insulated and Sheathed,Steel tape ArmoredControl Cable | 0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors,in cable ditches,Be able towithstand stronger external mechanical force |
4 6 | 4-14 | |||
10 | 4-14 | |||
KVVR | Copper Conductor,PVC Insulated and Sheathed,Flexible ControlCable | 0.5-2.5 | 4-61 | Installation indoors where flexibility and movability arerequired |
KVVRP | Copper Conductor,PVC Insulated and Sheathed,Braiding shieldedFlexible Control Cable | 0.5 0.75 1.0 | 4-61 | Installation indoors where flexibility shielding and movabilityare required |
1.5 2.5 | 4-48 | |||
KYJV | Copper Conductor,XLPE Insulated and PVC Sheathed ControlCable | 0.75 1.0 1.5 2.5 | 2-16 | Permanent installation indoors,in cable ditches orpipes |
4 6 | 2-14 | |||
10 | 2-10 | |||
KYJVP | Copper Conductor,XLPE Insulated,Braiding Shielded,PVC SheathedControl Cable | 0.75 1.0 1.5 2.5 | 2-61 | Permanent installation indoors,in cable ditches or pipes whereshielding is required |
4 6 | 2-14 | |||
10 | 2-10 | |||
KYJV22 | Copper Conductor,XLPE Insulated,Steel-tape Armoured,PVC SheathedControl Cable | 0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors,in cable ditches,pipes orunderground Be cable to with stand stronger external mechanicalforce |
4 6 | 4-14 | |||
10 | 4-10 | |||
KYJVP2 | Copper Conductor,XLPE Insulated,Copper tape Screened,PVC SheathedControl Cable | 0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors,in cable ditches or pipes whereshielding is required |
4 6 | 4-14 | |||
10 | 4-10 | |||
KYJVR | Copper Conductor,XLPE Insulated,PVC Sheathed Flexible ControlCable | 0.5-2.5 | 4-61 | Installation indoors where flexibility and movability arerequired |
KYJVRP | Copper Conductor,XLPE Insulated,Braiding Shielded,PVC SheathedFlexible Control Cable | 0.5 0.75 1.0 | 4-61 | Installation indoors where flexibility shielding and movabilityare required |
1.5 2.5 | 4-48 |
4.Service Conditions
(1) The long-time working temperature of conductor of PVCinsulated cable is 70oC
The long-time working temperature of conductor of XLPE insulatedcable is 90oC
(2) The temperature for laying the cables can not be lower than0oC.Permissible bending radius(r):unarmoured cable:r≥6D;(D: outer diameter ofthe cable);armoured or copper-tape screened cable:r≥12D;shielded flexiblecable:r≥6D