Control cable are suitable for the wiring of electricalcontrolling equipments and instrument,monitoring and so on.
1.Standard
The products can be produced according to the standard GB9330-1988,and thefactory can also manufacture the cables in accordance with other standards.
2.Scope of Application
The products are suitable for the wiring of electrical controlling equipmentsand instrument,monitoring and controlling return circuit,electrical protectionand measurement in power distribution unit under the circumstance that the ratedvoltage is up to 450/750V AC.
3.Type& Specification
Type | Name | Section Area(mm2) | No. of Core | Application Site |
KVV | Copper Conductor,PVC Insulated and Sheathed Control Cable | 0.75 1.0 1.5 2.5 | 2-16 | Permanent installation indoors,in cable ditches or pipes |
4 6 | 2-14 | |||
10 | 2-10 | |||
KVVP | Copper Conductor,PVC Insulated and Sheathed,Braiding ShieldedControlCable | 0.75 1.0 1.5 2.5 | 2-61 | Permanent installation indoors,in cable ditches or pipes where shielding isrequired |
4 6 | 2-14 | |||
10 | 2-10 | |||
KVVRP | Copper Conductor,PVC Insulated and Sheathed,Braiding shielded FlexibleControl Cable | 0.5 0.75 1.0 | 4-61 | Installation indoors where flexibility shielding and movability arerequired |
1.5 2.5 | 4-48 | |||
KYJV | Copper Conductor,XLPE Insulated and PVC Sheathed Control Cable | 0.75 1.0 1.5 2.5 | 2-16 | Permanent installation indoors,in cable ditches or pipes |
4 6 | 2-14 | |||
10 | 2-10 | |||
KYJVP | Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed ControlCable | 0.75 1.0 1.5 2.5 | 2-61 | Permanent installation indoors,in cable ditches or pipes where shielding isrequired |
4 6 | 2-14 | |||
10 | 2-10 | |||
KYJV22 | Copper Conductor,XLPE Insulated,Steel-tape Armoured,PVC Sheathed ControlCable | 0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors,in cable ditches,pipes or underground Be cableto with stand stronger external mechanical force |
4 6 | 4-14 | |||
10 | 4-10 | |||
KYJVP2 | Copper Conductor,XLPE Insulated,Copper tape Screened,PVC Sheathed ControlCable | 0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors,in cable ditches or pipes where shielding isrequired |
4 6 | 4-14 | |||
10 | 4-10 | |||
KYJVR | Copper Conductor,XLPE Insulated,PVC Sheathed Flexible Control Cable | 0.5-2.5 | 4-61 | Installation indoors where flexibility and movability arerequired |
KYJVRP | Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed FlexibleControl Cable | 0.5 0.75 1.0 | 4-61 |
4.Performance Characteristics
1)YZ model rated voltage Uo/u is 300/500V,T=YC model is 450/750V.
2) Long time allow working temperature of wire core is not more than 65oC
3)W model cable has the property of durability,so it is suitable for outdoorwork and the work touching oil pollution.
4) ZR model cable has the property of fire-resistance.
5.Model Name and Usage:(See Table1)
Model | Name | Main Usage |
YQ,YQW | Light Model Rubber Sheath Flexible | Used for light portable electric equipment and tools |
YZ,YZW | Middle Model Rubber Sheath Flexible Cable | Used for various portable electric equipment and tools |
YC,YCW | Heavy Model Rubber Sheath Flexible Cable | Used for various portable electric equipment which can bear larger mechanicalforce effect |