- For 3-phase, four wire, WYEapplications
- Cost-effective, universal 3-phase filters
- Good attenuation over the complete frequency range of 10kHz to 30MHz
- Two different mounting styles available
Available Part Numbers
Click on any part number for 3D CAD models, customer drawings, distributor stock status and eCommerce Links.
Flange Mount | Bulkhead Mount |
16AYA6A | 16AYA6 |
16AYA10 | 25AYA6 |
25AYA6A | 36AYA6 |
36AYA6A | 50AYA6 |
36AYA10 | |
50AYA6A | |
63AYA6A | |
63AYA10 | |
100AYA6A |
Specifications
Maximum leakage current, each Line to Ground: | ||
@ 120 VAC 60 Hz | 1.62mA | |
@ 250 VAC 50 Hz | 2.82mA | |
Hipot rating (one minute): | ||
Line to Ground | 1500 VAC | |
Line to Line | 1450 VDC | |
Operating Frequency: | 50 / 60 Hz | |
Rated voltage (max.): | ||
Phase to Phase | 440 VAC | |
Phase to Ground | 250 VAC | |
Rated Current: | 16A to 50A | |
Operating Ambient Temperature Range (at rated current Ir): | ||
-10°C to +40°C | ||
In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculated as follows: Io = Ir √(85-Ta)/45 |
Electrical Schematic
Case Styles
AYA6A (Flange mount with screw terminals)
Typical Dimensions: | ||
Mounting Slots (4): | ..425 x .254 [10.8 x 6.6] | |
16 & 25A Terminals (8): | 8-32 Torque 26 lbf-in. [2.94 N-m] max. | |
36A Terminals (8): | 10-32 Torque 27 lbf-in. [3.05 N-m] max. | |
50, 63 & 100A Terminals (8): | 1/4-20 Torque 56 lbf-in. [6.33 N-m] max. |
AYA6 (Bulkhead mount with screw terminals)
36AYA10
Typical Dimensions: | ||
Mounting Holes (4): | M5 x 8 | |
16 & 25A Terminals (8): | 8-32 Torque 26 lbf-in. [2.94 N-m] max. | |
36A Terminals (8): | 10-32 Torque 27 lbf-in. [3.05 N-m] max. | |
50A Terminals (8): | 1/4-20 Torque 56 lbf-in. [6.33 N-m] max. |
Typical Dimensions: | ||
Mounting Slots (4): | ..425 x .254 [10.8 x 6.6] | |
Terminal blocks (8): | 4mm² Torque 7.08 lbf-in. [0.8N-m] max. | |
Ground terminal (1): | M5 Torque 26.58 lbf-in. [3.0 N-m] max. |
36AYA10
Typical Dimensions: | ||
Mounting Slots (4): | ..425 x .254 [10.8 x 6.6] | |
Terminal blocks (8): | 10mm² Torque 15.93 lbf-in. [1.8 N-m] max. | |
Ground terminal (1): | M5 Torque 26.58 lbf-in. [3.0 N-m] max. |
63AYA10
Typical Dimensions: | ||
Mounting Slots (4): | ..425 x .254 [10.8 x 6.6] | |
Terminal blocks (8): | 16mm² Torque 20.35 lbf-in. [2.3 N-m] max. | |
Ground terminal (1): | M6 Torque 53.1 lbf-in. [6.0 N-m] max. |
Part No.ABCDE*(max.)(max.)(max.)(max.)(max.)16AYA6 / A
25AYA6 / A7.914.371.975.945.51201.0111.050.0151.0140.0
36AYA6 / A
50AYA6 / A7.914.372.565.945.51201.0111.065.0151.0140.0
63AYA6 / A
100AYA6A7.914.372.565.945.51201.0111.050.0151.0140.0
16AYA106.974.371.975.945.51177.0111.050.0151.0140.0
36AYA107.884.372.565.945.51200.0111.065.0151.0140.0
63AYA1010.985.082.528.436.26279.0129.064.0214.0159.0
* Does not apply to bulkhead models
Minimum Insertion Loss in dB:Measured in closed 50 ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
Current Rating | Frequency - MHz | |||||||
.01 | .05 | .1 | .5 | 1 | 5 | 10 | 30 | |
16A | 2 | 11 | 19 | 52 | 53 | 70 | 61 | 30 |
25A | 2 | 12 | 19 | 46 | 49 | 64 | 54 | 27 |
36A | 1 | 10 | 18 | 49 | 54 | 63 | 57 | 32 |
50A | 1 | 8 | 14 | 43 | 47 | 63 | 53 | 29 |
63A | 2 | 10 | 22 | 50 | 60 | 75 | 70 | 55 |
100A | 1 | 15 | 22 | 55 | 60 | 65 | 55 | 50 |
Current Rating | Frequency - MHz | |||||||
.01 | .05 | .1 | .5 | 1 | 5 | 10 | 30 | |
16A | 14 | 31 | 30 | 82 | 87 | 76 | 77 | 47 |
25A | 20 | 36 | 38 | 85 | 81 | 68 | 69 | 33 |
36A | 20 | 39 | 36 | 86 | 78 | 65 | 62 | 35 |
50A | 20 | 30 | 38 | 85 | 82 | 67 | 66 | 38 |
63A | 30 | 40 | 45 | 90 | 85 | 70 | 70 | 60 |
100A | 20 | 35 | 45 | 80 | 80 | 65 | 60 | 55 |