Ordering Information
Available Part Numbers
Click on any part number for 3D CAD models, customer drawings, distributor stock status and eCommerce Links.
16AYC10B | 110AYC10B |
25AYC10B | 150AYC10B |
36AYC10B | 150AYC10B-95 |
63AYC10B | 180AYC10B |
80AYC10B | 200AYC10B |
Maximum leakage current, each Line to Ground: | |||
@ 120 VAC 60 Hz: | @ 250 VAC 50 Hz: | ||
16A | 62 mA | 106 mA | |
25 & 36A | 68 mA | 118 mA | |
63A | 74 mA | 128 mA | |
80, 100 & 150A | 74 mA | 129 mA | |
180 & 200A | 111 mA | 192 mA | |
Hipot rating (one minute): | |||
Line to Ground | 1850 VDC | ||
Line to Line | 1850 VDC | ||
Line to Neutral | 1450 VDC | ||
Operating Frequency: | 50 / 60 Hz | ||
Rated voltage (max.): | |||
Phase to Phase | 480 VAC | ||
Phase to Ground | 277 VAC | ||
Rated Current: | 16A to 200A | ||
Operating Ambient Temperature Range (at rated current Ir): | |||
-10°C to +40°C | |||
In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculated as follows: Io = Ir √(85-Ta)/45 |
Electrical Schematic
Case Styles
80, 110 & 150 AYC10B / -95
80, 110 & 150 AYC10B / -95
180 & 200AYC10B
Minimum Insertion Loss in dB: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Measured in closed 50 ohm system | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Common Mode / Asymmetrical (Line to Ground) | Differential Mode / Symmetrical (Line to Line) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|