Basic Info.
  • Brand Name: CONTEC 
  • Specification: patient monitor,heart monitors 
  • Export Area: Worldwide 
  • Model No.: CMS6000B 
  • Place of Origin: Hebei  
Supply Capacity
  • Packing:DHL,EMS,TNT
Patient Monitor
 
CMS6000B
5 parameters
Features:
1.8.4 color TFT display
2.Suitable for adult, pediatric and neonatal patient
3.Basic parameters (ECG, SpO2, NIBP) in a durable case for bedside monitoring and  transport monitotring
4..Audible and visual alarms with adjustable alarm ranges
5..Networkable with CONTEC  central monitoring system
6..Powerful data management and storage capacity
ECG
1.Lead type:5-lead
2.Input: RA; LA; RL; LL; V
3.Sweep speed: 12.5mm/s, 25mm/s, 50mm/s
4.Accuracy: ±1bpm or ±1%, whichever is greater
5.Protection: Withstand 4000VAC/50Hz voltage in  isolation against electrosurgical and defibrillation
6.S-T detection: YES, Arrhythmia analysis: YES
7.Alarm: YES, audible and visual alarm, alarm events recallable
NIBP  
1.Method: Oscillometry
2.Operation modes: Manual/Automatic/STAT  
3.Measurement unit: mmHg/KPa selectable
4.Measurement types: Systolic, Diastolic, Mean  
5.Over-pressure protection: YES
SpO2  
Measurement range: 0-100%
Accuracy: ±2digit (70~100%);  
0~69% unspecified
Respiration
Method: RA-LL impedance
Pediatric/Neonatal: 6-150rpm
Alarm range: Adult: 6-120rpm
Pediatric/Neonatal: 6-150rpm
Apnea alarm: YES
Temperature
Resolution: 0.1
Channel: Dual-channel
Alarm range: 0-50
Option:
EtCO2
Measurement Mode: Side-stream or mainstream
Measurement range: EtCO2: 0-99mmHg
Accuracy: CO2 concentration
Apnea alarm: YES
IBP
Channel: 2 channels
Pressure transducer: Sensitivity: 5( mV/V/mmHg)
Transducer sites: ART, PA, CVP, RAP, LAP, ICP
Alarm range: -10~300mmHg
Standard Configuration:
ECG, NIBP,  SpO2,  RESP,2-TEMP,Network
Optional:
2-IBP,ETCO2,Thermal Recorder

Send message to this supplier
Mr. Billy Lee (Sales Mgr.)
Tel: 86-335-8015414
Mobile: 8613930309647
Enter between 20 to 3,000 chatacters.
Contact Method
Contec Medical System Co.,Ltd.(CHINA)
NO.24 HUANGHE WEST ROAD,QETDZ, Qinhuangdao, Hebei, China (Mainland) / 066004
Fax: 86-335-8015590
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center