PGⅡtest Rapid Test poct Kits for fluorescence immunoassay

Trade Term: FOB,CFR,CIF,DAT,FAS,DDP,DAP,CIP,CPT,FCA,EXW
Payment Terms: T/T,L/C,D/A,D/P,WU,Paypal,Money Gram
Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews
Basic Info.
  • Brand Name: NORMAN 
  • Methodology: Fluorescence Immunoassay 
  • Brand Name: Norman 
  • Place of Origin: Jiangsu, China (Mainland) 
  • Test time: 15mins 
  • Specimen: serum 
  • Packing: IN CARTON 
  • Manufacturer: Independent R & D 
  • Service: International after-sales 
  • Delivery Detail: depend on quantity 
  • Means of Transport:: Ocean,Air 
  • Model No.: NRM-FI-1000 
  • Place of Origin: Jiangsu  
  • Min.Order: 1000 Piece/Pieces
  • Means of Transport: Ocean, Air
Supply Capacity
  • Production Capacity: 1,000,000.00/Month
  • Packing:IN CARTON
  • Delivery Date: TWO WEEKS AFTER PAYMENT

                         PGⅡtest Rapid Test poct Kits


Methodology                                                                                                      

Fluorescence  Immunoassay


Fluorescence Immunoassay Analyzer                                                     


Product Show                                                                                                    


Size                                                                                                                         

21cmx25cmx13.5cm


Weight                                                                                                                  

3.5kg


Product Name                                                                                                   

General Name:PGⅡ Test Kit(Immunofluorescence)


Package                                                                                                                

Test card: Aluminum foil pouch 1pc/bag, desiccant

Package size: 25pcs/box


PG II                                                                                                                      

The status and function of gastric mucosa.

Dynamic detection of gastric function.

Early screening of gastric cancer.


Package                                                                                                               


Test card: Aluminum foil pouch 1pc/bag, desiccant

Package size: 25pcs/box


Intended use                                                                                                      


The ratio of PGⅠand PGⅡ(PGR) has the effect of "Serological biopsy" 

for gastric mucosa. It is one of the effective ways for monitoring gastric mucosa 

lesion such as gastritis, gastric ulcer and etc, estimating the process of atrophic gastritis.


Main components                                                                                            


1.Test kit contains: 25 test cards and an IC card

   The test card is composed of plastic shell and test strip.

   The main components of test strip: Sample pad, bonding pad, nitrocellulose membrane,  

   Anti-MIgG, absorbent paper, PVC base plate.

2.Diluents (3ml×1 bottle): composed of phosphate, surface active agent, etc. PH=7.4±0.2.

    

Materials required (but not provided):

1.Timer

2.Centrifuge tube

3.Pipette

4.Disposable tips


Clinical significance                                                                                       


Atrophy of gastric fundus gland duct

Intestinal metaplasia

Pseudopyloric metaplasia

Evaluation indicator of gastric cancer

 

Advantage                                                                                                           


1.High sensitivity:2ng/ml.

2.Overall evaluation: evaluate PGI and PGI/PGII.

3.Small sample size: 30ul (serum).

4.Wide linear range:2-70ng/ml.

 

Performance analysis                                                                                     


correlation analysis between Norman PGII and Abbott PGII


 

Applicable department                                                                                  


Gastroenterology, internal medicine, surgery, traditional Chinese medicine

PGI content in different gastritis and explanation of reason

Superficial gastritis

Chronic mild, moderate atrophic gastritis

Chronic severe atrophic gastritis. 


Interpretation of test results                                                                       


1.The analysis of test results are accomplished by  immune-fluorescence  quantitative 

analyzer of  our company's NORMAN series.

2.The concentration of PGⅡ in the unknown samples can be read directly in the

corresponding batch of ID card standard curve by fluorescence signal value we measured.

The default results use ng/ml as a unit.


Performance Indicators                                                                                


1.Detection limit:  ≤2ng/ml

2.Linear range:2-70ng/ml,the linear correlation coefficient r should not be less than 

0.9900 in this range.

3.Accuracy: Recovery rate is within the range (80% ~ 120%)

4.Repeatability: CV≤15%.

5.Difference between batches: CV≤15%.


Storage and Stability                                                                                      


1.The reagent box must be stored from 4 to 30℃, and the period of validity is 12 months. 

2.The reagent strip must be used within 1 hour once its foil pouch has been opened. 

3.Do not use the strip beyond the expiration date printed on the outside of the box. 


Quality Control                                                                                                 


Using immunefluorescence quantitative analyzer and relevant X detection kit (immune-

fluorescence techniques) to test quality control product,repeat 10 times, calculate average 

and CV. 


If CV≤15%, the average in the scale of quality control product, 

then the instrument and reagent performance can meet requirements.




Package & Delivery                                                                                          



Related Products                                                                                              



About us                                                                                                               

_Attitude

Admittedly, the ability of candidates is an important criterion for talent selection, but 

working attitude is the power source, only keep diligent working attitude and passion, 

people can blossom and bear fruit at his position.


_Morality

On the basis of corresponding ability, personal qualitie of employees is an important 

standard to measure whether employees was mainly used and promoted.

_Practice

On the one hand Norman provides all kinds of training opportunity and further study to

staff, on the other hand establishs a training mechanism of " push, hold, pull" , offers talent 

suitable position, promotes them in rapid growth.

_Development

In the field of biology and medicine, Norman had set sail, with broad development 

prospects and space. All professionals can find their own development space and stage in 

Norman. Also adheres to the principle that pay and return are reciprocity, provides each

employee a reasonable pay, shares the victory of enterprise development, achieves a win-

win between enterprises and employees.


Part of the R&D department                                                                        




Agent Wanted                                                                                                    

If you are interested in working with us, please feel free to contact. 


Why us                                                                                                                  

Manufacturer and Exporter for nearly 10 years with self R&D Research Center;

Professional After-Sale service with On-site support worldwide; 

CE/ISO13485/TUV/Rohs/SGS Certifications

OEM and ODM are available !




Send message to this supplier
Ms. Ying Qin (Department Manager)
Tel: 86-25-58602219
Mobile: 13814717578
Enter between 20 to 3,000 chatacters.
Contact Method
Nanjing Norman Biological Technology Co., Ltd
No. 197 Pharmaceutical Valley Road, Jiangbei New Area, Nanjing, Jiangsu, China (Mainland) / 210000
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center