Fully-automatic Pensky-Martens Closed-Cup Flash Point Tester

Price: 1.0 USD
Trade Term: FOB
Payment Terms: T/T
Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews
Basic Info.
  • Flash Point Tester: Open-Cup Flash Point Tester 
  • Pensky-Martens Tester: Closed-Cup Flash Point Tester 
  • Closed-Cup Flash Point Tester: Pensky-Martens Closed-Cup Flash Point Tester 
  • Model No.: GD-261D 
  • Place of Origin: Chongqing  
  • Min.Order: 1 Set/Sets
  • Means of Transport: Ocean, Air, Land
Supply Capacity
  • Production Capacity: 500Sets/per Month
  • Packing:Wooden Case
  • Delivery Date: 10days

GD-261D Fully-automatic Pensky-Martens Closed-Cup Flash Point Tester

Introduction:

This instrument is designed and manufactured as per standards GB/T 261-2008 Determination of Flash Point - Pensky-Martens closed cup method and ASTM D93 Standard Test Method for Flash Point by Pensky-Martens Closed Cup Tester. It is used to make determination of the closed cup flash point of the petroleum products.

 

Features:

l It adopts LCD screen to display. Full English man-machine dialog interface. It can preset the parameters of expected flash point, sample mark number, atmospheric pressure, test date, etc. It has menu to prompt and input function of guide type.

l It adopts simulation tracking display the function curve of temperature rising and test time. It has prompt functions of English mis-operation, test date and test time.

l It is equipped with standard RS-323,485 computer port. The lower computer can save 100 groups of historical data. The test data can be saved for a long time, transmitted and modified if the instrument being connected with computer.

l It can correct the influence of atmospheric pressure and calculate the correction automatically.

l Differential detection. Automatically correct the systematic deviation.

l Automatically open the lid, ignite, detect and print test data. The test arm lifting up and down automatically.

l It adopts electric ignition to fire light the gas flame. It will light only need to press the button.

l Humanized design, beautiful and safe. Easy to operate.

 

Specifications:

Power supply

AC(220±10%)V,50Hz

Flash point determination

Range: Ambient to 300℃

Repeatability: ≤3℃

Reproducibility:≤6℃

Accuracy:0.1℃

Heating rate

Pr℃edure A: (5~6)℃/min, Pr℃edure B: (1~1.6)℃/min

Automatic control and manually adjustable

Stirring rate

Pr℃edure A: (90~120)RPM, Pr℃edure B: (250±10)RPM

Automatic control and manually adjustable

Igniting mode

Electric ignition. Gas flame diameter:3.2mm~4.8mm

Working condition

Ambient temperature:(10~40)℃

Relative humidity:≤80%

Maximum power consumption

500W

Dimension

520*360*310mm

 