Key Features:
1:Advanced performance due to the CPU control
2:Low initial investment and flexible for future expansion
3:Wide input voltage range with high frequency technology
4:LCD Display with Advanced Monitoring for Easy UPS Management
5:Perfect protection against battery under voltage, overload and short circuit
6:Auto restart after utility power restore when UPS shutdown due to battery low
7:Selection of Single or Dual Utility Input to enhance the utility power protection
8:Smart local and distant monitoring capability with RS232 port, and compatible with SNMP
9:Direct DC cold start function offers emergency on UPS by battery without utility power
10:Flexible Battery Configuration. It can be set on the front panel with 28/30/32 Units of Batteries
11:Advanced IGBT power components, which enhancing the overall reliability and conversion efficiency
12:Intelligent battery management directly checking and setting charge and setting charge and discharge of battery on LCD extends battery life
Applications:
security systems,Telecommunication equipment,Electric equipment,Office Automation,,Network Rooms,Education System,Medical Equipment,Financial System Securities System
Technical Specification
Queen Star Series Q6K-20Kva | ||||||||
Model | Q6K | Q6KL | Q10K | Q10KL | 31Q10KL | 31Q15KL | 31Q20KL | |
Capacity | 6KVA/4800W | 10KVA/8000W | 15KVA/12KW | 20KVA/16KW | ||||
Input | Nominal Voltage | 220/230/240Vac | 380/400/415Vac | |||||
Voltage Range | 176~276Vac (1P2W+G) | 304~478Vac (3P4W+G) | ||||||
Current | 31A (max) | 50A (max) | 50A (max) | 75A (max) | 100A (max) | |||
Frequency | 46~54Hz/56~64Hz | |||||||
Power Factor | ≥0.99 | |||||||
Output | Voltage | 220/230/240± 2%Vac (1P2W+G) | ||||||
Frequency | 50/60Hz(adjustable) 50/60Hz± 5% (Line mode) 50/60Hz ± 0.05Hz ( Battery mode) | |||||||
Current | 27.3A | 45A | 68A | 91A | ||||
Power Factor | 0.8lag | |||||||
Waveform | Pure Sine Wave | |||||||
Waveform Distortion | Line load<2% | Line load<3% | ||||||
Back-up Time | Full Load | ≥7′ | Depends on external batteries bank's Capacity | ≥5′ | Depends on external batteries bank's Capacity | |||
Half Load | ≥20′ | ≥13′ | ||||||
Battery Nominal Voltage | 192/240Vdc | |||||||
Transfer Time | 0ms | |||||||
Overload Capacity | >105% 1min, >120% 30s transfer to bypass, shut down in 1min | |||||||
Communication | SNMP,RS-232,USB+Intelligent Slot | |||||||
Operating Environment | Temperature | 0C~40ºC | ||||||
Humidity | 15%~90% | |||||||
Dimension | Width (mm) | 260 | 260 | 260 | 260 | 260 | ||
Depth (mm) | 560 | 533 | 560 | 533 | 560 | |||
Height (mm) | 717 | 501 | 717 | 501 | 717 | |||
Net Weight(Kg) | 68 | 18 | 70 | 20 | 28 | 30 | 30 | |
*Specification are subject to change without prior notice |