Application:
The series of AC, DC solenoids for hydraulic valves apply to control circuits of AC 50Hz, voltage up to 220V and of single phase DC power, voltage up to 220V, and are used as power units for joint-designed type hydraulic-pressure back pressure controlled valves in the country.
Specifications
parameters\type |
MFZ1-2.5YC
|
MFB1-2.5YC
|
MFZ1-4YC
|
MFB1-4YC
|
MFB1-5.5YC
|
MFZ1-5.5YC
|
MFZ1-7YC
|
MFB1-7YC
|
Rated voltage(V) |
12 24 110 220
|
110 220
|
12 24 110 220
|
110 220
|
110 220
|
12 24 110 220
|
12 24 110
|
110 220
|
Rated Force(N) |
≥25
|
≥25
|
≥40
|
≥40
|
≥55
|
≥55
|
≥70
|
≥70
|
Rated Stroke(mm) |
3
|
3
|
6
|
6
|
4
|
4
|
7
|
7
|
Full Stroke(mm) |
≥6.2
|
≥6.2
|
≥12
|
≥12
|
≥8.5
|
≥8.5
|
≥10.5
|
≥10.5
|
Consumption Power(W) |
≤26
|
≤26
|
≤40
|
≤40
|
≤40
|
≤40
|
≤40
|
≤40
|
Endurable oil pressure(MPa) |
6.3
|
6.3
|
6.3
|
6.3
|
6.3
|
6.3
|
6.3
|
6.3
|
Operation frequency(T/h) |
7200
|
7200
|
7200
|
7200
|
7200
|
7200
|
3600
|
3600
|
External Shape and Installing Dimension
Note:
Electromagnet adopts plug bases meeting the requirements of the ISO4000 standard. The user can choose at his needs between the two specifications, including plug base with indicator light and plug base without indicator light. The voltage specification of the plug base with indicator light should conform to the voltage specification of the electromagnet itself.
The manual jogger of the electromagnet should be controlled by hand only in the debugging or critical situation. However, when the backing pressure of the system is pretty high and difficult to adjust, the user should use the cross head driver to slowly push the manual jogger instead of using impact force so as to avoid destroying the manual jogger and the surface of the direction hole which will cause the electromagnet to leak the oil and unable to reset.
When the electromagnet is used Bi-direction, it should be insured that the two electromagnets cannot be electrified at the same time so as to avoid the malfunction of the electromagnet.
Overcurrent protection system should be used in the connection part between electric control system and electromagnet so as avoid burning the electromagnet and electronic control units under improper condition.