Mining explosion proof solenoids for hydraulics

Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews
Basic Info.
  • Type: Others 
  • Certification: CE 
  • Brand Name: Tonly 
  • Place of Origin: Zhejiang  
Supply Capacity
  • Production Capacity: 1800000
  • Packing:carton
  • Delivery Date: 20
Parameters\Type
Rated Voltage(V)
Rated Force(N)
Rated Stroke(mm)
Full travel(mm)
Working pressure(MPa)
Duty cycle(%)
Operating frequency(T/h)
DTBF-39/24YZ
24
39
3
≥6.2
6.3
60
3000
DTBF-39/36YZ
36
39
3
≥6.2
DTBF-39/127YB
127
39
3
≥6.2
DTBF-39/220YB
220
39
3
≥6.2
DTBF-69/24YZ
24
69
4
≥6.2
DTBF-69/36YZ
36
69
4
≥6.2
DTBF-69/127YB
127
69
4
≥6.2
DTBF-69/220YB
220
69
4
≥6.2


 

External Shape and Installing Dimension
Note:
1.Using four M6*30 Hexagon screws to installed solenoid on corresponding solenoid valves.
2.Using S4 hex spanner to remove the four M5*15 Hexagon screws on 'terminal box" Remove the 'terminal box '.
3.Loosing'clamp bolt' to take out 'pads','dust-proofpad',and 'cable seals'.And throw away 'dust mat'.
4.If using three-core cable (users provides) with 8mm external diameter that complies with the requirements of GB12972-1991 'Mining sott rubber-sheathed cable' and MT818-1999 'Mine flame-retardant cable','cable rings','gaskets' and 'clamping bolts' shall be put on the cable following the sequence as listed.the cable goes into 'terminal box' at the rotation spot of 'Clamp bolts'. Striping the socket off the cable,and connect to the corresponding screws on the terminal box respectively.
5.Using S4 hex spanner to fix the four M5*15 Hexagon screws in the shell of the electromagnet.
6.If using the cable (user proxndes) with external diameter less than 4mm2 that comply with the requirements of GB12972-1991 "Mining soft rubber-sheathed cable' and MT818-1999 'Mine flame-retardant cable'.The external grounding lines shall be connected with the protection 'grounding' lines of equipment used.
Explanation Of Sample:
If client have special requirements,we can adjust the connect dimension,the extended length of push pin,and the supply voltage between solenoids and valve body.
Characteristic curve for reference only.
If the application is beyond the catalogue,please contact with us
The main performance parameter is obtained in the conditions of lab.Finally explanation and changing of the parameters by Tonly

Send message to this supplier
Mr. Chen Hualin
Tel: 86-574-88452652
Enter between 20 to 3,000 chatacters.
Contact Method
Ningbo Yinzhou Tongli Hydraulic Electrical Factory
China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center