CMS9000 Multi-parameter patient Monitor
Features:
1. Color TFT Screen, waveform up to 8 channels
2. Light and portable with build-in rechargeable battery
3. UP to 10 kinds of monitor parameters
4. Arrhythmia analysis, pace-marker detection and S-T Segmentanalysis
5. 72 hour storage and review of trend grams and tables, 40 second review of olographic Wavefo RMS.
6. Built-in recorder(option)
7. All-round monitor of adult, pediatric and neonatal.
8. Electrosurgical unit and defibrillation protected
9. Standard parameters: ECG, NIBP, SpO2, Respiration, Temperature, Pulse rate
10. Option parameters: EtCO2, CO, IBP, Thermal Printer
ECG
1. 5-lead or 3-lead selectable
2. Input: 5-lead: RA; LA; RL; LL; V or R; L; N; F; C
3. Lead selection: I; II; III; AvR; AvL; AvF; Vx; CAL
4. Gain selection: 12.5mm/s, 25mm/s, 50mm/s
5. Accuracy:? Bpm or? %, whichever is greater
6. Protection: Withstand 4000VAC/50Hz voltage in isolation against electrosurgical and defibrillation
7. Calibration signal: 1mV? %
8. Operation modes: Diagnostic, Monitor, Surgery
9. Alarm range: Adult: 15-300bpm
10. Pediatric/Neonatal: 15-350bpm
11. Alarm range: -2.0mV~2.0mV
12. S-T detection: YES, Arrhythmia analysis: YES
13. Alarm: YES, audible and visual alarm, alarm events recallable
NIBP
1. Method: Oscillometry
2. Operation modes: Manual/Automatic/STAT
3. Measurement unit: MmHg/KPa selectable
4. Measurement types: Systolic, Diastolic, Mean
5. Measurement range: Adult: 10-270mmHg
6. Over-pressure protection: YES
7. Resolution: 1mmHg
8. Accuracy: Mean error and standard deviation per ANSI/AAMI SP-10
9. Alarm: Systolic, Diastolic, Mean
SpO2
1. Measurement range: 0-100%
2. Accuracy:? Digit (70~100%);
3. 0~69% unspecified
4. Alarm range: 0-100%
Respiration
1. Method: RA-LL impedance
2. Pediatric/Neonatal: 6-150rpm
3. Alarm range: Adult: 6-120rpm
4. Pediatric/Neonatal: 6-150rpm
5. Apnea alarm: YES
Temperature
1. Resolution: 0.1 C
2. Channel: Dual-channel
3. Alarm range: 0-50 C
Option:
EtCO2
1. Measurement Mode: Side-stream or mainstream
2. Measurement range: EtCO2: 0-99mmHg
3. Accuracy: CO2 concentration
4. Apnea alarm: YES
CO
1. Method: Thermo-dilution
2. Measurement range: CO: 0.1-20 lit. /min.
IBP
1. Channel: 2 channels
2. Pressure transducer: Sensitivity: 5( mV/V/mmHg)
3. Transducer sites: ART, PA, CVP, RAP, LAP, ICP
4. Alarm range: -10~300mmHg