- For 3-phase, four wire, WYE Applications
- Filters each of the three lines plus the neutral and ground line
- Both common mode and differential mode suppression from 50kHz to 30MHz
- Effective for both balanced and unbalanced loads
- Ground choke included
- Optional end bell kits available to shield input and output terminals
- AYP single stage for lower noise environments
- AYT dual stage provides highest performance
Available Part Numbers
Click on any part number for 3D CAD models, customer drawings, distributor stock status and eCommerce Links.
20AYP6C | 20AYT6C |
30AYP6C | 30AYT6C |
45AYP6C | 45AYT6C |
60AYP6C | 60AYT6C |
Maximum leakage current, each Line to Ground: | ||
@ 120 VAC 60 Hz | 1.4 mA | |
@ 250 VAC 50 Hz | 3.4 mA | |
Hipot rating (one minute): | ||
Line to Ground | 1500 VAC | |
Neutral to Ground | 1500 VAC | |
Line to Neutral | 1450 VDC | |
Operating Frequency: | 50 / 60 Hz | |
Rated voltage (max.): | ||
Phase to Phase | 440 VAC | |
Phase to Neutral / Ground | 250 VAC | |
Rated Current: | 20A to 60A | |
Operating Ambient Temperature Range (at rated current Ir): | ||
-10°C to +40°C | ||
In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculated as follows: Io = Ir √(85-Ta)/45 |
AYP6C Models
AYT6C Models
Case Styles
Case Dimensions
Part No. | A* | B | C | D | E |
(max.) | (max.) | (max.) | ± .030 | ± .015 | |
± .76 | ± .38 | ||||
20AYP6C 30AYP6C | 8.82 | 5.57 | 2.56 | 4.616 | 1.50 |
224.0 | 141.5 | 65.0 | 117.2 | 38.1 | |
45AYP6C 60AYP6C | 9.43 | 6.92 | 4.82 | 5.950 | 3.75 |
239.5 | 175.8 | 122.4 | 151.1 | 95.3 | |
20AYT6C 30AYT6C | 13.82 | 5.57 | 2.56 | 4.616 | 1.50 |
351.0 | 141.5 | 65.0 | 117.2 | 38.1 | |
45AYT6C 60AYT6C | 13.83 | 6.92 | 4.82 | 5.950 | 3.75 |
351.3 | 175.8 | 122.4 | 151.1 | 95.3 | |
* For end bell covering terminals and connections, add: | |||||
20A & 30A | 5.57 | ||||
141.48 | |||||
45A & 60A | 6.45 | ||||
163.83 |
Accessories
Mounting bracket kit with captive nuts:
AA400: 20A & 30A versions
AA405: 45A & 60A versions
Protective cover for use with mounting bracket (Available in Europe only):
AA406A: 20A & 30A versions
AA407A: 45A & 60A versions
End bell kit (bracket and cover) with captive nuts:AA406: 20A & 30A versions
AA407: 45A & 60A versions
Additional captive nuts
AA401: 10 nuts
Performance Data
Typical Insertion Loss Measured in closed 50 ohm system 20AYP6C 30AYP6C 45AYP6C 60AYP6C 20AYT6C 30AYT6C 45AYT6C 60AYT6C
Minimum Insertion Loss in dB: Measured in closed 50 ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
Current Rating Frequency - MHz .05 .1 .15 .5 1 5 10 30 AYP6C 20A 22 32 39 55 56 65 65 54 30A 15 24 30 55 55 61 63 50 45A 8 19 25 49 49 56 58 45 60A 5 16 22 50 50 54 54 47 AYT6C 20A 45 63 70 75 75 75 75 65 30A 29 53 61 75 75 75 75 60 45A 15 39 43 75 75 75 75 50 60A 12 37 46 75 75 75 70 45
Current Rating Frequency - MHz .05 .1 .15 .5 1 5 10 30 AYP6C 20A 20 38 50 65 65 65 60 52 30A 18 28 43 65 65 65 59 48 45A 8 20 27 60 65 65 56 43 60A 20 24 27 60 65 65 56 50 AYT6C 20A 27 56 65 70 70 70 70 70 30A 17 46 55 75 75 75 75 70 45A 14 41 50 75 75 75 75 65 60A 26 50 58 75 75 75 75 60